Revistas
Revista:
JOURNAL OF ARRHYTHMIA
ISSN:
1880-4276
Año:
2023
Vol.:
39
N°:
1
Págs.:
82 - 83
Autores:
Wise, B.; Albarran Rincon, R.; De Lossada Juste, A. ; et al.
Revista:
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY
ISSN:
1383-875X
Año:
2022
Vol.:
63
N°:
1
Págs.:
103 - 108
Purpose Advanced non-fluoroscopic mapping systems for radiofrequency ablation (RFA) have shown to be an effective treatment of atrial fibrillation. This study analyzes the resource usage and subsequent costs associated with the implementation of an ultra-high density mapping system (UHDMS) compared to non-ultra-high density mapping systems (NUHDMS). Methods This retrospective observational study included 120 patients (18 years or older) with paroxysmal or persistent atrial fibrillation who underwent RFA for de novo pulmonary vein isolation guided either by an UHDMS (n=63) or NUHDMS (n=57) for their index procedure. We compared patient characteristics, short- and long-term procedural outcomes, resource usage, and clinical outcomes followed up to 16 months between the two treatment groups. The cost analysis was conducted from the perspective of a single center in Spain (Clinica Universidad de Navarra). Results Neither baseline patient characteristics nor complication rate differed between groups. Repeat RFAs following recurrent arrhythmia at 16 months was lower in the UHDMS patient group than in the NUHDMS group (6 vs. 14, respectively; P=0.027). The average total cost per patient was euro1,600 lower in the UHDMS group, compared to the NUHDMS group (euro11,061 and euro12,661, respectively; P=0.03). Conclusion In patients treated with an NUHDMS, 25% had a repeat ablation for recurrent arrhythmia, whereas only 9% of patients treated with a UHDMS had one (61% relative risk reduction), resulting in an average cost saving per patient of euro1,600.
Autores:
Solimene, F. (Autor de correspondencia); Stabile, G.; Ramos, P.; et al.
Revista:
CLINICAL CARDIOLOGY
ISSN:
0160-9289
Año:
2022
Vol.:
45
N°:
6
Págs.:
597 - 604
Background The antral region of pulmonary veins (PV)s seems to play a key role in a strategy aimed at preventing atrial fibrillation (AF) recurrence. Particularly, low-voltage activity in tissue such as the PV antra and residual potential within the antral scar likely represent vulnerabilities in antral lesion sets, and ablation of these targets seems to improve freedom from AF. The aim of this study is to validate a structured application of an approach that includes the complete abolition of any antral potential achieving electrical quiescence in antral regions. Methods The improveD procEdural workfLow for cathETEr ablation of paroxysmal AF with high density mapping system and advanced technology (DELETE AF) study is a prospective, single-arm, international post-market cohort study designed to demonstrate a low rate of clinical atrial arrhythmias recurrence with an improved procedural workflow for catheter ablation of paroxysmal AF, using the most advanced point-by-point RF ablation technology in a multicenter setting. About 300 consecutive patients with standard indications for AF ablation will be enrolled in this study. Post-ablation, all patients will be monitored with ambulatory event monitoring, starting within 30 days post-ablation to proactively detect and manage any recurrences within the 90-day blanking period, as well as Holter monitoring at 3, 6, 9, and 12 months post-ablation. Healthcare resource utilization, clinical data, complications, patients' medical complaints related to the ablation procedure and patient's reported outcome measures will be prospectively traced and evaluated. Discussion The DELETE AF trial will provide additional knowledge on long-term outcome following a structured ablation workflow, with high density mapping, advanced algorithms and local impedance technology, in an international multicentric fashion. DELETE AF is registered at (NCT05005143).
Revista:
JACC-CLINICAL ELECTROPHYSIOLOGY
ISSN:
2405-500X
Año:
2022
Vol.:
8
N°:
5
Págs.:
595 - 604
Objectives: This analysis was performed to evaluate the transition of local impedance (LI) drop during pulmonary vein isolation (PVI) to durable block and mature lesion formation based on 3-month mapping procedures.
Background: A radiofrequency catheter measuring LI has been shown to be effective for performing PVI in patients with paroxysmal atrial fibrillation. Previous analysis has demonstrated LI drop to be predictive of pulmonary vein segment conduction block during an atrial fibrillation ablation procedure.
Methods: Fifty-eight patients who had undergone LI-blinded de novo PVI returned for a 3-month mapping procedure. PVI ablation circles were divided into 16 anatomic segments for classification (durable block or gap), and the median LI drop within segments with an interlesion distance of ¿6 mm was compared. A total of 51 data sets met the criteria for segmental analysis of LI performance.
Results: At the 3-month procedure, PV connection was confirmed in at least 1 PV segment in 35 of the included patients. LI drop outperformed generator impedance drop as a predictor of durable conduction block (area under the receiver-operating characteristic curve: 0.79 vs 0.68; P = 0.003). Optimal LI drops were identified by left atrial region (anterior/superior: 16.9 ¿ [sensitivity: 69.1%; specificity: 85.0%; positive predictive value for durable conduction block: 97.7%]; posterior/inferior:14.2 ¿ [sensitivity: 73.8%; specificity: 78.3%; positive predictive value: 96.9%]). Starting LI before radiofrequency (RF) application was significantly different among healthy, gap, and mature scar tissue and was also a contributing factor to achieving an optimal LI drop (85.2% of RF applications with a starting LI of ¿110 ¿ achieved the optimal regional drop or greater).
Conclusions: LI drop is predictive of durable PV segment isolation. Preablation starting LI is associated with the magnitude of LI drop. These findings suggest that a regional approach to RF ablation guided by LI combined with careful interlesion distance control may be beneficial in patients with paroxysmal atrial fibrillation (Electrical Coupling Information From the Rhythmia HDx System and DirectSense Technology in Subjects With Paroxysmal Atrial Fibrillation [LOCALIZE]; NCT03232645).
Revista:
RADIOLOGIA
ISSN:
0033-8338
Año:
2021
Vol.:
63
N°:
5
Págs.:
391 - 399
Objective: To analyze the anatomic characteristics of the left atrium and pulmonary veins in individuals undergoing ablation for atrial fibrillation and to identify possible anatomic factors related with recurrence. Material and methods: We retrospectively reviewed the CT angiography studies done to plan radiofrequency ablation for atrial fibrillation in 95 patients (57 men; mean age, 65 +/- 10 y). We reviewed the anatomy of the pulmonary veins and recorded the diameters of their ostia as well as the diameter and volume of the left atrium. We analyzed these parameters according to the type of arrhythmia and the response to treatment. Results: In 71 (74.7%) patients, the anatomy of the pulmonary veins was normal (i.e., two right pulmonary veins and two left pulmonary veins). Compared to patients with paroxysmal atrial fibrillation, patients with persistent atrial fibrillation had slightly larger diameter of the left pulmonary veins (left superior pulmonary vein 17.9 +/- 2.6 mm vs. 16.7 +/- 2.2 mm, p = 0.04; left inferior pulmonary vein 15.3 +/- 2 mm vs. 13.8 +/- 2.2 mm, p = 0.009) and larger left atrial volume (91.9 +/- 24.9 cm(3) vs. 70.7 +/- 20.3 mm(3), p = 0.001). After 22.1 +/- 12.1 months' mean follow-up, 41 patients had sinus rhythm. Compared to patients in whom the sinus rhythm was restored, patients with recurrence had greater left atrial volume (81.4 +/- 23.0 mm(3) vs. 71.1 +/- 23.2 mm(3), p = 0.03). No significant differences in pulmonary vein diameters or clinical parameters were observed between patients with recurrence and those without. Conclusion: The volume of the left atrium is greater in patients with persistent atrial fibrillation and in those who do not respond to ablation.
Revista:
JOURNAL OF ELECTROCARDIOLOGY
ISSN:
0022-0736
Año:
2021
Vol.:
64
Págs.:
1 - 2
Autores:
Das, M. (Autor de correspondencia); Luik, A.; Shepherd, E.; et al.
Revista:
EUROPACE
ISSN:
1099-5129
Año:
2021
Vol.:
23
N°:
7
Págs.:
1042 - 1051
Aims Radiofrequency ablation creates irreversible cardiac damage through resistive heating and this temperature change results in a generator impedance drop. Evaluation of a novel local impedance (LI) technology measured exclusively at the tip of the ablation catheter found that larger LI drops were indicative of more effective lesion formation. We aimed to evaluate whether LI drop is associated with conduction block in patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein isolation (PVI). Methods and results Sixty patients underwent LI-blinded de novo PVI using a point-by-point ablation workflow. Pulmonary vein rings were divided into 16 anatomical segments. After a 20-min waiting period, gaps were identified on electroanatomic maps. Median LI drop within segments with inter-lesion distance <= 6 mm was calculated offline. The diagnostic accuracy of LI drop for predicting segment block was assessed using receiver operating characteristic analysis. For segments with inter-lesion distance <= 6 mm, acutely blocked segments had a significantly larger LI drop [19.8 (14.1-27.1) Omega] compared with segments with gaps [10.6 (7.8-14.7) Omega, P < 0.001). In view of left atrial wall thickness differences, the association between LI drop and block was further evaluated for anterior/roof and posterior/inferior segments. The optimal LI cut-off value for anterior/roof segments was 16.1 Omega (positive predictive value for block: 96.3%) and for posterior/inferior segments was 12.3 Omega (positive predictive value for block 98.1%) where inter-lesion distances were <= 6 mm. Conclusion The magnitude of LI drop was predictive of acute PVI segment conduction block in patients with paroxysmal AF. The thinner posterior wall required smaller LI drops for block compared with the thicker anterior wall.
Revista:
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY
ISSN:
1383-875X
Año:
2021
Vol.:
62
N°:
2
Págs.:
357 - 362
Purpose Remote system operation technology was developed and applied to a non-fluoroscopic navigation system in order to overcome Spanish mobility restrictions caused by Covid-19 pandemic infection and subsequently used routinely. Methods and results Fifty consecutive complex ablations were performed in different days using this technology. All these procedures were assisted remotely with the only intervention of a field clinical specialist located at his home who took full control of the navigation system (keyboard, mouse, and screen) and had bidirectional real-time audio/video feedback with the operating physician. Once the connection was established, the remote field clinical specialist replicated the Rhythmia screen at the remote location with all its features, and interacted identically with the physician, essentially with no perceptible differences from being physically present. There were neither interruptions nor perceptible delays in the bidirectional communications between the remote field clinical specialist and the operating physician during the procedures. Video signal delay ranged from 265 to 325 ms. All the procedures were uneventful. Conclusions Remote system operation allowed full teleoperation of a non-fluoroscopic navigation system (keyboard, mouse, and screen) as well as bidirectional real-time audio/video feedback with the operating physician, providing a fully autonomous remote assistance in 50 complex ablation procedures. This technology ensures workflow continuity and optimal workforce flexibility and has relevant and promising implications in the field of training, teaching, and resource optimization that deserves further development.
Revista:
JOURNAL OF MEDICAL INTERNET RESEARCH
ISSN:
1438-8871
Año:
2020
Vol.:
22
N°:
12
Págs.:
e21436
Background: The Prevention With Mediterranean Diet (PREDIMED) trial supported the effectiveness of a nutritional intervention conducted by a dietitian to prevent cardiovascular disease. However, the effect of a remote intervention to follow the Mediterranean diet has been less explored. Objective: This study aims to assess the effectiveness of a remotely provided Mediterranean diet-based nutritional intervention in obtaining favorable dietary changes in the context of a secondary prevention trial of atrial fibrillation (AF). Methods: The PREvention of recurrent arrhythmias with Mediterranean diet (PREDIMAR) study is a 2-year multicenter, randomized, controlled, single-blinded trial to assess the effect of the Mediterranean diet enriched with extra virgin olive oil (EVOO) on the prevention of atrial tachyarrhythmia recurrence after catheter ablation. Participants in sinus rhythm after ablation were randomly assigned to an intervention group (Mediterranean diet enriched with EVOO) or a control group (usual clinical care). The remote nutritional intervention included phone contacts (1 per 3 months) and web-based interventions with provision of dietary recommendations, and participants had access to a web page, a mobile app, and printed resources. The information is divided into 6 areas: Recommended foods, Menus, News and Online resources, Practical tips, Mediterranean diet classroom, and Your personal experience. At baseline and at 1-year and 2-year follow-up, the 14-item Mediterranean Diet Adherence Screener (MEDAS) questionnaire and a semiquantitative food frequency questionnaire were collected by a dietitian by phone. Results: A total of 720 subjects were randomized (365 to the intervention group, 355 to the control group). Up to September 2020, 560 subjects completed the first year (560/574, retention rate 95.6%) and 304 completed the second year (304/322, retention rate 94.4%) of the intervention. After 24 months of follow-up, increased adherence to the Mediterranean diet was observed in both groups, but the improvement was significantly higher in the intervention group than in the control group (net between-group difference: 1.8 points in the MEDAS questionnaire (95% CI 1.4-2.2; P<.001). Compared with the control group, the Mediterranean diet intervention group showed a significant increase in the consumption of fruits (P<.001), olive oil (P<.001), whole grain cereals (P=.002), pulses (P<.001), nuts (P<.001), white fish (P<.001), fatty fish (P<.001), and white meat (P=.007), and a significant reduction in refined cereals (P<.001), red and processed meat (P<.001), and sweets (P<.001) at 2 years of intervention. In terms of nutrients, the intervention group significantly increased their intake of omega-3 (P<.001) and fiber (P<.001), and they decreased their intake of carbohydrates (P=.02) and saturated fatty acids (P<.001) compared with the control group. Conclusions: The remote nutritional intervention using a website and phone calls seems to be effective in increasing adherence to the Mediterranean diet pattern among AF patients treated with catheter ablation.
Revista:
AMERICAN HEART JOURNAL
ISSN:
0002-8703
Año:
2020
Vol.:
220
Págs.:
127 - 136
Background Atrial fibrillation (AF) is the most common cardiac arrhythmia. Catheter ablation aims to restore sinus rhythm. However, relapses occur in up to 30% of patients. A Mediterranean diet (MedDiet) enriched with extra-virgin olive oil (EVOO) substantially reduced the incidence of AF in the PREDIMED trial. The PREDIMAR will test a similar intervention in secondary prevention. Methods PREDIMAR is a multicenter, randomized, single-blind trial testing the effect of a MedDiet enriched with EVOO to reduce tachyarrhythmia relapses after AF ablation. The primary outcome is the recurrence of any sustained atrial tachyarrhythmia after ablation (excluding those occurring only during the first 3 months after ablation). The target final sample size is 720 patients (360 per group) recruited from 4 Spanish hospitals. A remote intervention, maintained for 2 years, is delivered to the active intervention group including periodic phone calls by a dietitian and free provision of EVOO. The control group will receive delayed intervention after trial completion. Routine electrocardiogram (ECG) and Holter ECG are performed, and a portable cardiac rhythm monitoring device is provided to be worn by participants during 15 months. Results Recruitment started in March 2017. Up to July 2019, 609 patients were randomized (average inclusion rate: 5.3 patients/wk). Retention rates after 18 months are >94%. Conclusions If our hypothesis is confirmed, the utility of the MedDiet enriched with EVOO in slowing the progression of AF will be proven, preventing recurrences and potentially reducing complications.
Revista:
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY
ISSN:
1045-3873
Año:
2019
Vol.:
30
N°:
8
Págs.:
1231 - 1240
Introduction Ultrahigh-density-voltage mapping (uHD(V)M) is a new tool that can add new insights into the pathophysiology of atrial fibrillation (AF). The aim of this study was to evaluate the performance of uHD(V)M in predicting postablation AF recurrence (AFR). Methods and Results We included 98 consecutive patients undergoing pulmonary vein isolation for AF (40.8% persistent) using an uHD(V)M system and followed for 1 year. The left atrium (LA) mean voltage (V-m) and the V-slope (slope of the voltage histogram calculated by linear interpolation, with the relative frequency on the vertical axis and the bipolar potential on the horizontal axis) were calculated from 12 567 +/- 5486 points per map. Patients with AFR (N = 29) had lower V-m and higher V-slope as compared with patients without AFR (N = 69). Receiver operating characteristic curves identified V-m as the strongest predictor of AFR, with a higher incidence of AFR in patients with V-m 0.758 mV (57.6%) or lower than patients with V-m higher than 0.758 mV (15.4%; P < .0001). Among patients with V-m higher than 0.758 mV, patients with V-slope 0.637 or higher exhibited higher (P = .043) AFR incidence (31.3%) than patients with V-slope lower than 0.637 (10.2%). This classification showed incremental predictive value over relevant covariables. V-m values were lower and V-slope values were higher in patients that progressed from paroxysmal to persistent AF. Patients with V-slope 0.637 or higher had a 14.2% incidence of postablation atypical atrial flutter, whereas patients with V-slope lower than 0.637 did not present this outcome. Conclusions The risk of AFR, atrial flutter, and progression from paroxysmal to persistent AF can be detected by quantitative analysis of LA uHD(V)M identifying diverse patterns of atrial substrate alterations.
Revista:
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
ISSN:
0735-1097
Año:
2019
Vol.:
73
N°:
12
Págs.:
1398 - 1410
Background A combination of circulating biomarkers associated with excessive myocardial collagen type-I cross-linking or CCL+ (i.e., decreased carboxy-terminal telopeptide of collagen type-I to matrix metalloproteinase-1 ratio) and with excessive myocardial collagen type-I deposition or CD+ (i.e., increased carboxy-terminal propeptide of procollagen type-I) has been described in heart failure (HF) patients and associates with poor outcomes.
Objectives The purpose of this study was to investigate whether the CCL+CD+ combination of biomarkers associates with atrial fibrillation (AF).
Methods Biomarkers were analyzed in serum samples from 242 HF patients (study 1) and 150 patients referred for AF ablation (study 2). Patients were classified into 3 groups (CCL¿CD¿, CCL+CD¿ or CCL¿CD+, and CCL+CD+) in accordance to biomarker threshold values. Left atrial electroanatomic high-density mapping was performed in 71 patients from study 2.
Results In study 1, 53.7% patients had AF at baseline and 19.6% developed AF (median follow-up 5.5 years). Adjusted odds and hazard ratios associated with baseline and new-onset AF, respectively, were both ¿3.3 (p ¿ 0.050) in CCL+CD+ patients compared with CCL¿CD¿ patients, with nonsignificant changes in the other group. In study 2, 29.3% patients had AF recurrence during 1-year post-ablation.
Revista:
EUROPACE
ISSN:
1099-5129
Año:
2019
Vol.:
21
N°:
2
Págs.:
250 - 258
Aims Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is usually associated to conduction gaps in pulmonary veins (PVs). Our objective was to characterize gaps in patients with recurrences after a first radiofrequency (RF) or cryoballoon (CB) PVI procedure, using a high-density mapping (HDM) system. Methods and results Fifty patients with AF recurrence after a first PVI procedure (pre-RF 25 patients; pre-CB 25 patients) were included at two centres. Activation map (AM) and voltage map (VM) of the left atrium and PVs were built using the HDM Rhythmia (R) system. Superior PVs were reconnected more frequently in both groups. Right PVs were reconnected more frequently in pre-RF patients. Pre-RF patients had more reconnected veins than pre-CB patients (meanstandard deviation: 3.00 +/- 0.96 vs. 1.88 +/- 1.13; P<0.001) and more gaps (4.84 +/- 2.06 vs. 2.16 +/- 1.49; P<0.001). Gaps in the VM were wider in pre-CB patients (16.5 +/- 9.5mm vs. 12.1 +/- 4.8mm; P=0.006). There was a gap in 179 of the 800 PV segments analysed (22%); 52% were identified in both AM and VM maps; 39% only in the AM and 8% only in the VM. The highest sensitivity and specificity for gap detection was obtained with VM in pre-CB patients and with AM in pre-RF patients. Conclusion In conclusion, HDM seems to be a useful and precise tool to detect conduction gaps after a first PVI procedure. The anatomical pattern and location of gaps depends on the technique used previously, usually being multiple, smaller, and better detected by AM after RF, and fewer, wider, and better detected by VM after CB.
Revista:
EUROPACE
ISSN:
1099-5129
Año:
2019
Vol.:
21
N°:
Supl. 3
Págs.:
2 - 4
Revista:
CIRCULATION
ISSN:
0009-7322
Año:
2018
Vol.:
137
N°:
7
Págs.:
743 - 746
Revista:
EUROPACE
ISSN:
1099-5129
Año:
2018
Vol.:
20
N°:
Supl. 3
Págs.:
F351 - F358
Aims Maps obtained by means of electroanatomic high-density mapping (HDM) systems have shown their use in the identification of conduction gaps in experimental atrial linear lesion models. The objective of this study was to assess the use of HDM in the recognition of reconnection gaps in pulmonary veins (PV) in redo atrial fibrillation (AF) ablation procedures. Methods and results One hundred and eight patients were included in a non-randomized study that assessed the recognition of reconnection gaps in PV by means of HDM compared to a control group that received conventional non-fluoroscopic guidance with a circular multipolar catheter (CMC). Among the HDM group, adequate recognition of reconnection gaps was obtained in 60.99% of the reconnected PVs (86 of 141), a figure significantly higher than that achieved with analysis of CMC recorded signals (39.66%, 48 of 121; P = 0.001). The number of applications and total radiofrequency time were also significantly lower in the HDM group (12.46 +/- 6.1 vs. 15.63 +/- 7.7 and 7.61 +/- 3 vs. 9.29 +/- 5; P = 0.02, and P = 0.03, respectively). At the 6-month follow-up, no statistically significant differences were found in recurrence of AF or any other atrial tachycardia between the HDM group (8 patients, 14.8%) and the control group in (16 patients, 29.6%; P = 0.104). Conclusion An analysis of the high-density activation maps allows greater precision in the identification of reconnection gaps in PV, which results in lower radiofrequency time for the new isolation.
Revista:
CIRCULATION
ISSN:
0009-7322
Año:
2018
Vol.:
138
N°:
4
Págs.:
439 - 440
Revista:
REVISTA ESPAÑOLA DE CARDIOLOGÍA (ENGLISH ED.)
ISSN:
1885-5857
Año:
2017
Vol.:
70
N°:
9
Págs.:
706 - 712
INTRODUCTION AND OBJECTIVES:
Rhythmia is a new nonfluoroscopic navigation system that is able to create high-density electroanatomic maps. The aim of this study was to describe the acute outcomes of atrial fibrillation (AF) ablation guided by this system, to analyze the volume provided by its electroanatomic map, and to describe its ability to locate pulmonary vein (PV) reconnection gaps in redo procedures.
METHODS:
This observational study included 62 patients who underwent AF ablation with Rhythmia compared with a retrospective cohort who underwent AF ablation with a conventional nonfluoroscopic navigation system (Ensite Velocity).
RESULTS:
The number of surface electrograms per map was significantly higher in Rhythmia procedures (12 125 ± 2826 vs 133 ± 21 with Velocity; P < .001), with no significant differences in the total procedure time. The Orion catheter was placed for mapping in 99.5% of PV (95.61% in the control group with a conventional circular mapping catheter; P = .04). There were no significant differences in the percentage of PV isolation between the 2 groups. In redo procedures, an ablation gap could be identified on the activation map in 67% of the reconnected PV (40% in the control group; P = .042). The measured left atrial volume was lower than that calculated by computed tomography (109.3 v 15.2 and 129.9 ± 13.2 mL, respectively; P < .001). There were no significant differences in the number of complications.
CONCLUSIONS:
The Rhythmia system is effective for AF ablation procedures, with procedure times and safety profiles similar to conventional nonfluoroscopic navigation systems. In redo procedures, it appears to be more effective in identifying reconnected PV conduction gaps.
Revista:
REVISTA ESPAÑOLA DE CARDIOLOGÍA (ENGLISH ED.)
ISSN:
1885-5857
Año:
2017
Vol.:
70
N°:
7
Págs.:
598 - 600
Revista:
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY
ISSN:
0147-8389
Año:
2017
Vol.:
40
N°:
5
Págs.:
545 - 550
BackgroundFirst description of a technique for left atrium transseptal puncture (TSP) with minimal radiation exposure by using the nonfluoroscopic MediGuide tracking system (MG; St. Jude Medical, St. Paul, MN, USA) without the assistance of intracardiac echocardiography. MethodsThis study included 31 consecutive patients with atrial fibrillation undergoing an MG-assisted percutaneous catheter ablation procedure. A Brockenbrough transseptal needle (BRK) is connected to a standard pressure transducer through a two-input valve. Then, an MG-enabled guidewire is inserted so that its tip exactly matches the BRK's distal tip. After the acquisition of two short radioscopic cine-loops we are able to trace the needle tip on the MG screen, performing the usual TSP maneuver but without fluoroscopy. Successful left atrium access is confirmed by noticing the change in the pressure curve and by advancing the guidewire into the left pulmonary veins. As a control group, 31 matched patients who underwent atrial fibrillation ablation with fluoroscopically guided, pressure-monitored TSP were included. ResultsSixty-two MG-assisted TSP attempts were performed; all but two were successfully accomplished without changing to the conventional technique (96.7%). The mean total fluoroscopy time, until the double transseptal access was performed, was 26.65 37.97 seconds in the MG group and 129.13 +/- 37.77 seconds in the conventional-TSP group (P < 0.001). No major complications occurred during any of the procedures. ConclusionThis new technique for TSP using MG is feasible and can be performed with minimal radiation exposure without the need for additional imaging techniques, achieving a significant reduction of fluoroscopy time.
Revista:
JOURNAL OF ATRIAL FIBRILLATION
ISSN:
1941-6911
Año:
2016
Vol.:
8
N°:
5
Págs.:
61-66
Revista:
EUROPACE
ISSN:
1099-5129
Año:
2016
Vol.:
18
N°:
1
Págs.:
57-63
A history of ¿2000 h of vigorous endurance training, tall stature, abdominal obesity, and OSA are frequently encountered as risk factors in patients with Ln-AF. Fewer than 2000 total hours of high-intensity endurance training associates with reduced Ln-AF risk.
Autores:
N; V; m; et al.
Revista:
ARCHIVOS DE BRONCONEUMOLOGIA
ISSN:
0300-2896
Año:
2016
Vol.:
52
N°:
1
Págs.:
17-23
CPAP therapy only partially improves heart rate variability, and exclusively during waking hours, and reduces incidence of atrial tachycardia, both of which can influence cardiovascular morbidity and mortality in sleep apnea¿hypopnea syndrome patients.
Revista:
RESPIRATORY RESEARCH
ISSN:
1465-9921
Año:
2014
Vol.:
15
Págs.:
54
OSA induces selective atrial fibrosis in a chronic murine model, which can be mediated in part by the systemic and local inflammation and by decreased collagen-degradation. MSCs transplantation prevents atrial fibrosis, suggesting that these stem cells could counterbalance inflammation in OSA.
Autores:
e; e; f; et al.
Revista:
AMERICAN HEART ASSOCIATION. JOURNAL. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE
ISSN:
2047-9980
Año:
2014
Vol.:
3
N°:
5
Págs.:
e000877
The linear block at the LA roof is not associated with an improved clinical outcome compared with PV isolation alone.
Revista:
INTERNATIONAL JOURNAL OF CARDIOLOGY
ISSN:
0167-5273
Año:
2013
Vol.:
168
N°:
4
Págs.:
4093-7
The study groups included 659 consecutive patients undergoing CA between 2003 and 2011: TMP group (n = 61), HF group (n = 36) and control group (n = 562). Compared to controls, patients with TMP were younger, had a shorter AF course and more often had persistent AF. Regarding echocardiographic parameters, the TMP group had lower LVEF (40% vs. 62%, P < 0.05), larger left atrial diameter (LAD: 46 vs. 41 mm, P < 0.05) and LV end-diastolic diameter (LVEDD: 55 vs. 51 mm, P < 0.05) compared to controls, with significant improvement at six-month follow-up, including those patients with AF recurrence. The probability of being arrhythmia-free did not differ between the TMP group and the other groups after a first or last procedure. The only independent predictor of AF recurrence was LAD.
CONCLUSIONS:
Patients with tachycardiomyopathy secondary to AF benefit from CA, with a significant improvement in LVEF, LVEDD and LAD. The outcome after CA of this group did not differ from patients with no structural cardiomyopathy.
Nacionales y Regionales
Título:
Ensayo aleatorizado de prevención con dieta mediterránea de arritmias recurrentes (estudio predimar) en pacientes con fibrilación auricular
Código de expediente:
46/2016
Investigador principal:
Miguel Ruiz-Canela López
Financiador:
GOBIERNO DE NAVARRA
Convocatoria:
2016 GN SALUD
Fecha de inicio:
08/12/2016
Fecha fin:
08/12/2019
Importe concedido:
47.385,16€
Otros fondos:
-
Título:
Predimar-omicas: Ensayo aleatorizado de dieta Mediterránea en recurrencias de fibrilación autricular post-ablación. Efectos de la dieta a largo plazo y mecanismos de acción subyacentes.
Código de expediente:
PI20/01751
Investigador principal:
Miguel Ruiz-Canela López
Financiador:
INSTITUTO DE SALUD CARLOS III
Convocatoria:
2020 AES Proyectos de investigación
Fecha de inicio:
01/01/2021
Fecha fin:
31/12/2023
Importe concedido:
83.490,00€
Otros fondos:
Fondos FEDER
Título:
Predimar
Código de expediente:
PI17/00718
Investigador principal:
Miguel Ruiz-Canela López
Financiador:
INSTITUTO DE SALUD CARLOS III
Convocatoria:
AES2017 PROYECTOS DE INVESTIGACIÓN
Fecha de inicio:
01/01/2018
Fecha fin:
31/12/2021
Importe concedido:
52.030,00€
Otros fondos:
Fondos FEDER