Revistas
Revista:
CIRUGIA ESPAÑOLA
ISSN:
0009-739X
Año:
2023
Vol.:
101
N°:
2
Págs.:
143 - 145
Autores:
Levillain, H. (Autor de correspondencia); Bagni, O.; Deroose, CM.; et al.
Revista:
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING
ISSN:
1619-7070
Año:
2021
Vol.:
48
N°:
5
Págs.:
1570 - 1584
Purpose A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (Y-90)-resin microspheres. Methods A steering committee of 23 international experts representing all participating specialties formulated recommendations for SIRT with Y-90-resin microspheres activity prescription and post-treatment dosimetry, based on literature searches and the responses to a 61-question survey that was completed by 43 leading experts (including the steering committee members). The survey was validated by the steering committee and completed anonymously. In a face-to-face meeting, the results of the survey were presented and discussed. Recommendations were derived and level of agreement defined (strong agreement >= 80%, moderate agreement 50%-79%, no agreement <= 49%). Results Forty-seven recommendations were established, including guidance such as a multidisciplinary team should define treatment strategy and therapeutic intent (strong agreement); 3D imaging with CT and an angiography with cone-beam-CT, if available, and Tc-99m-MAA SPECT/CT are recommended for extrahepatic/intrahepatic deposition assessment, treatment field definition and calculation of the Y-90-resin microspheres activity needed (moderate/strong agreement). A personalised approach, using dosimetry (partition model and/or voxel-based) is recommended for activity prescription, when either whole liver or selective, non-ablative or ablative SIRT is planned (strong agreement). A mean absorbed dose to non-tumoural liver of 40 Gy or less is considered safe (strong agreement). A minimum mean target-absorbed dose to tumour of 100-120 Gy is recommended for hepatocellular carcinoma, liver metastatic colorectal cancer and cholangiocarcinoma (moderate/strong agreement). Post-SIRT imaging for treatment verification with Y-90-PET/CT is recommended (strong agreement). Post-SIRT dosimetry is also recommended (strong agreement). Conclusion Practitioners are encouraged to work towards adoption of these recommendations.
Revista:
EJNMMI RESEARCH
ISSN:
2191-219X
Año:
2021
Vol.:
11
N°:
1
Págs.:
23
Purpose: To determine which imaging method used during radioembolization (RE) work-up: contrast-enhanced computed tomography (CECT), 99mTc-MAA-SPECT/CT or cone beam-CT (CBCT), more accurately predicts the final target volume (TgV) as well as the influence that each modality has in the dosimetric calculation.
Methods: TgVs from 99mTc-MAA-SPECT/CT, CECT and CBCT were consecutively obtained in 24 patients treated with RE and compared with 90Y PET/CT TgV. Using the TgVs estimated by each imaging modality and a fictitious activity of 1 GBq, the corresponding absorbed doses by tumor and non-tumoral parenchyma were calculated for each patient. The absorbed doses for each modality were compared with the ones obtained using 90Y PET/CT TgV.
Results: 99mTc-MAA-SPECT/CT predicted 90Y PET/CT TgV better than CBCT or CECT, even for selective or superselective administrations. Likewise, 99mTc-MAA-SPECT/CT showed dosimetric values more similar to those obtained with 90Y PET/CT. Nevertheless, CBCT provided essential information for RE planning, such as ensuring the total coverage of the tumor and, in cases with more than one feeding artery, splitting the activity according to the volume of tumor perfused by each artery.
Conclusion: The joint use of 99mTc-MAA-SPECT/CT and CBCT optimizes dosimetric planning for RE procedures, enabling a more accurate personalized approach.
Revista:
LIVER INTERNATIONAL
ISSN:
1478-3223
Año:
2015
Vol.:
35
N°:
6
Págs.:
1715-21
Single-session SIRT appeared to be as safe and had a similar impact on HRQoL as multiple sessions of TACE, suggesting that SIRT might be an alternative option for patients eligible for TACE.
Revista:
Journal of the American Academy of Dermatology
ISSN:
0190-9622
Año:
2011
Vol.:
65
N°:
5
Págs.:
893 - 906
There is significant confusion in the literature when describing vascular anomalies, and vascular malformations are often misnamed or incorrectly classified. Part I of this two-part series on the diagnosis and management of extensive vascular malformation
Revista:
Journal of the American Academy of Dermatology
ISSN:
0190-9622
Año:
2011
Vol.:
65
N°:
5
Págs.:
909 - 923
At least nine types of vascular malformations with specific clinical and radiologic characteristics must be distinguished in the lower limbs: Klippel¿Trénaunay syndrome, port-wine stain with or without hypertrophy, cutis marmorata telangiectatica congenit
Revista:
ANNALS OF SURGICAL ONCOLOGY
ISSN:
1068-9265
Año:
2011
Vol.:
18
N°:
7
Págs.:
1964 - 1971
Revista:
International Journal of Radiation Oncology, Biology, Physics
ISSN:
0360-3016
Año:
2010
Vol.:
77
N°:
5
Págs.:
1441 - 1448
Revista:
British Journal of Dermatology (Print)
ISSN:
0007-0963
Año:
2010
Vol.:
162
N°:
2
Págs.:
350 - 356
Revista:
Journal of vascular and interventional radiology (Print)
ISSN:
1051-0443
Año:
2010
Vol.:
21
N°:
8
Págs.:
1205 - 1212
Revista:
Cardiovascular and Interventional Radiology
ISSN:
0174-1551
Año:
2010
Vol.:
33
N°:
3
Págs.:
523 - 531