Revistas
Revista:
DIAGNOSIS
ISSN:
2194-802X
Año:
2023
Vol.:
10
N°:
3
Págs.:
281 - 297
Objectives: Remote self-collected capillary blood samples have been proposed as alternative to venous blood samples as an aid in telemedicine. The aim of this work is to compare the preanalytical and analytical performance of these two types of samples and to study the stability of common measurands in capillary blood.
Methods: Capillary and venous blood samples were collected in parallel from 296 patients in serum tubes to analyze 22 common biochemistry magnitudes after centrifugation and in EDTA tubes to analyze 15 hematologic magnitudes. Quality of the preanalytical process was assessed applying the model of quality indicator. 24 h stability at room temperature was studied by obtaining paired capillary samples. A questionnaire of assessment was conducted.
Results: Mean hemolysis index was higher in capillary samples compared to venous blood samples (p<0.001). Regression analysis and difference analysis showed no bias for all studied biochemistry parameters and hematologic parameters, except mean corpuscular volume (MCV), between capillary and venous blood samples. Regarding sample stability, percentage deviation was higher than the corresponding minimum analytical performance specification for ferritin, vitamin D, hematocrit, MCV, mean corpuscular hemoglobin concentration, platelets distribution wide, mean platelet volume and basophils. Finger pricking was perceived as less painful (p<0.05) than venipuncture in participants who undergo more than one blood test per year.
Conclusions: Capillary blood can be used as an alternative to venous blood for the studied parameters in automated common clinical analyzers. Cautious should be taken if samples are not analyzed within 24 h from the collection.
Revista:
CLINICA CHIMICA ACTA
ISSN:
0009-8981
Año:
2023
Vol.:
548
Págs.:
117502
Background and aims: Patients' response to treatment in differentiated thyroid cancer (DTC) is classified ac-cording to serum thyroglobulin concentrations (Tg), usually using the American Thyroid Association guidelines and considering potential interfering anti-thyroglobulin antibodies (Ab-Tg). We aim to evaluate the clinical implications of changing Tg and Ab-Tg quantification method. Material and methods: Tg and Ab-Tg were quantified in 82 serum samples (60 from DTC patients) by Elecsys and Access immunoassays. Results: Elecsys immunoassay rendered higher values of Tg than Access: mean bias 5.03 ng/mL (95%CI:-14.14-24.21). In DTC patients, there was an almost perfect agreement for response classification (kappa index = 0.833). Discrepancies appeared in patients with undetermined response, with a more tendency to subclassifi-cation with Access. Ab-Tg showed a poor correlation (r = 0.5394). When Elecsys cut-off was reduced to 43 IU/ mL, agreement for positive/negative classification improved from a kappa index of 0.607 to 0.650. Prospective study with personalized follow-up showed that only 6.3% of Tg results required an analytical confirmation, being confirmed 93% of them. Conclusions: Despite the biases observed, clinical impact of an analytical change is minimal in patients' man-agement. However, cautious and personalized follow-up period after the change is still mandatory, especially in patients with Tg levels between 0.2 and 1 ng/mL.
Revista:
SCIENTIFIC REPORTS
ISSN:
2045-2322
Año:
2022
Vol.:
12
N°:
1
Págs.:
9752
Breath tests used to evaluate carbohydrates malabsorption require baseline H2 and CH4 levels as low as possible. Test cancellation is recommended when exceeding certain cut-offs (H2 ¿ 20 ppm and CH4 ¿ 10 ppm). Although following preparation protocols, many patients have baseline levels above those cut-offs. We investigated if light walking can reduce baseline H2 and CH4 levels. We retrospectively analyzed baseline H2 and CH4 levels from 1552 breath tests. Baseline levels (B1), especially in H2, were lower when obtained at later hours of the day. In those with baseline levels above cut-off, re-sampling (B2) after light walking for one hour, decreased H2 levels 8 ppm (Q1-Q3: 1-18 ppm), and 2 ppm (Q1-Q3: 0-3 ppm) for CH4. Consequently, 40% of tests with elevated B1 levels, presented B2 levels below mentioned cut-offs. Ten percent of tests considered negative when using B1 for calculations, turned positive when using B2 instead. All positive tests when using B1 values, remained elevated when using B2. Re-sampling after light walking for one hour could allow test performance in those with previous elevated baseline levels, avoiding diagnosis delays. Using the second sample for delta calculations identifies positive patients for malabsorption that would have been considered negative.