Revistas
Revista:
OTOLARYNGOLOGY CASE REPORTS
ISSN:
2468-5488
Año:
2023
Vol.:
26
Págs.:
100501
Revista:
OTOLARYNGOLOGY CASE REPORTS
ISSN:
2468-5488
Año:
2023
Vol.:
26
Págs.:
100503
Revista:
JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH
ISSN:
1092-4388
Año:
2022
Vol.:
65
N°:
10
Págs.:
3789 - 3797
Purpose: The aims of this study were to analyze and characterize the irrintzi (a folkloric shout emitted in a single breath used by the Basque people) acoustically and to describe the mechanism by which it is emitted. Method: Thirty-six sound samples of 12 female volunteers were analyzed. Acoustic analysis included primarily fundamental frequency (fo), spectral analysis in the time domain with a narrowband filter, and the use of linear predictive coding (LPC). Laryngeal and pharyngeal movements while emitting an irrintzi were studied by fiberoptic nasal endoscopy. Postural and mandible movements were observed and video recorded. Movements of the larynx and the vocal tract were also studied by lateral pharyngo-laryngeal radioscopy. Results: The central part of an irrintzi spectrogram contains a peculiar, repeated M-shaped motif unseen in the spectrogram of any other human vocal emission, and intensity was over 90 dB SPL in all cases. fo was very high (1487 Hz) especially at the end of the irrintzi. Fiberoptic nasal endoscopy consistently revealed considerable elevation of the glottis, with the larynx swinging forward and retraction of the ventricular bands. Lateral radioscopy showed a very high larynx and a high tongue dorsum. Conclusions: The irrintzi is a sound emitted in a single breath and characterized by its shrillness and loudness, qualities that make it audible in noisy environments and over large distances and the vocal technique observed when it is produced can be explained by the Estill voice model (Steinhauer et al., 2017). The use of this technique may help in the treatment of voice disorders and improve efficiency in singers, teachers, actors, and people who use their voice at high volume or at high frequency.
Revista:
CLINICAL CASE REPORTS
ISSN:
2050-0904
Año:
2022
Vol.:
10
N°:
3
Págs.:
e05476
We report the case of a 48-year-old woman, a teacher, with recurrent severe dysphonia and multiple and different lesions at the same time in her vocal folds. The evolution of the lesions and the possible mechanism by which they have been associated in the same patient are commented.
Revista:
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH
ISSN:
1661-7827
Año:
2022
Vol.:
19
N°:
11
Págs.:
6934
Obstructive sleep apnea (OSA) is a common sleep disorder characterized by repetitive upper airway obstruction, intermittent hypoxemia, and recurrent awakenings during sleep. The most used treatment for this syndrome is a device that generates a positive airway pressure-Continuous Positive Airway Pressure (CPAP), but it works continuously, whether or not there is apnea. An alternative consists on systems that detect apnea episodes and produce a stimulus that eliminates them. Article focuses on the development of a simple and autonomous processing system for the detection of obstructive sleep apneas, using polysomnography (PSG) signals: electroencephalography (EEG), electromyography (EMG), respiratory effort (RE), respiratory flow (RF), and oxygen saturation (SO2). The system is evaluated using, as a gold standard, 20 PSG tests labeled by sleep experts and it performs two analyses. A first analysis detects awake/sleep stages and is based on the accumulated amplitude in a channel-dependent frequency range, according to the criteria of the American Academy of Sleep Medicine (AASM). The second analysis detects hypopneas and apneas, based on analysis of the breathing cycle and oxygen saturation. The results show a good estimation of sleep events, where for 75% of the cases of patients analyzed it is possible to determine the awake/asleep states with an effectiveness of >92% and apneas and hypopneas with an effectiveness of >55%, through a simple processing system that could be implemented in an electronic device to be used in possible OSA treatments.
Revista:
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY
ISSN:
0937-4477
Año:
2022
Vol.:
279
N°:
11
Págs.:
5347 - 5353
Purpose To describe the anatomic relationship of the lingual nerve with the lateral oropharyngeal structures. Methods An anatomic dissection of the lateral oropharyngeal wall was conducted in eight sides from four fresh-frozen cadaveric heads. Small titanium clips were placed along the lingual nerve and the most anterior and medial border of the medial pterygoid muscle. Radiological reconstructions were employed for optimal visualization; the coronal view was preferred to resemble the surgical position. The distance between the lingual nerve and the medial pterygoid muscle at its upper and lower portion was measured radiologically. The trajectory angle of the lingual nerve with respect to the pterygomandibular raphe was obtained from the intersection between the vector generated between the clips connecting the upper and lower portion of the medial pterygoid muscle with the vector generated from the lingual nerve clips. Results The mean distance from the upper portion of the medial pterygoid muscle and superior lingual nerve clips was 10.16 +/- 2.18 mm (mean +/- standard deviation), and the lower area of the medial pterygoid muscle to the lingual nerve was separated 5.05 +/- 1.49 mm. The trajectory angle of the lingual nerve concerning to the vector that describes the upper portion of the most anterior and medial border of the medial pterygoid muscle with its lower part was 43.73o +/- 11.29. Conclusions The lingual nerve runs lateral to the lateral oropharyngeal wall, from superiorly-inferiorly and laterally-medially, and it is closer to it at its lower third.
Revista:
JOURNAL OF VOICE
ISSN:
0892-1997
Año:
2021
Vol.:
35
N°:
6
Págs.:
930
Autores:
Moscoso-Barrera, W. D.; Agudelo-Otalora, L. M.; Moreno-Giraldo, A. M.; et al.
Revista:
F1000RESEARCH
ISSN:
2046-1402
Año:
2021
Vol.:
10
Págs.:
197
Obstructive sleep apnoea-hypopnoea syndrome (OSA) is a respiratory disorder characterised by repetitive obstruction of the upper airway, leading to several interruptions during sleep. It is currently one of the main public health problems worldwide and one of the main cardiovascular risk factors in developed and intermediate developing countries, whose populations are increasing in rates of obesity and age. One of the common treatments for OSA is a continuous positive airway pressure (CPAP) device, which pumps air through a hose, reaches a mask that the patient has over his or her nose and travels the airway, keeping the upper airway open during sleep and avoiding episodes of airway collapse. The problem is that CPAP is not accepted by some patients due to a lack of adaptation, so alternative treatments may be needed. For some years, there have been explorations of treatments related to electrical stimulation of the muscles of the upper airway as therapy to reduce the number of episodes of apnoea (measured through the apnoea¿hypopnoea index) during the night, strengthening these muscles through stimulation. This is the protocol of the first clinical study of a rehabilitation device for home use that not only provides functional stimulation of the upper-airway dilator muscles but also provides sensory stimulation. This device works by strengthening the dilating muscles of the upper respiratory tract and improving the sensory capacity of the laryngo-pharyngeal tract and is based on existing publications on the effectiveness of functional and somatosensory neurostimulation through neuroplasticity in the recovery of neurological deficits.
Revista:
JOURNAL OF CLINICAL MEDICINE
ISSN:
2077-0383
Año:
2021
Vol.:
10
N°:
9
Págs.:
1883
Study Objectives: Evaluating daytime neuromuscular electrical training (NMES) of tongue muscles in individuals with Primary Snoring and Mild Obstructive Sleep Apnea (OSA). Methods: A multicenter prospective study was undertaken in patients with primary snoring and mild sleep apnea where daytime NMES (eXciteOSA(R) Signifier Medical Technologies Ltd., London W6 0LG, UK) was used for 20 min once daily for 6 weeks. Change in percentage time spent snoring was analyzed using a two-night sleep study before and after therapy. Participants and their bed partners completed sleep quality questionnaires: Epworth Sleepiness Scale (ESS) and Pittsburgh Sleep Quality Index (PSQI), and the bed partners reported on the nighttime snoring using a Visual Analogue Scale (VAS). Results: Of 125 patients recruited, 115 patients completed the trial. Ninety percent of the study population had some reduction in objective snoring with the mean reduction in the study population of 41% (p < 0.001). Bed partner-reported snoring reduced significantly by 39% (p < 0.001). ESS and total PSQI scores reduced significantly (p < 0.001) as well as bed partner PSQI (p = 0.017). No serious adverse events were reported. Conclusions: Daytime NMES (eXciteOSA(R)) is demonstrated to be effective at reducing objective and subjective snoring. It is associated with effective improvement in patient and bed partner sleep quality and patient daytime somnolence. Both objective and subjective measures demonstrated a consistent ...
Revista:
SIMULATION IN HEALTHCARE
ISSN:
1559-2332
Año:
2021
Vol.:
16
N°:
5
Págs.:
367 - 371
Introduction: The AirSim Multi (TruCorp) airway simulator is used to practice exploration of the upper respiratory tract with a flexible endoscope to assess the nasal cavities, their structures and spaces (inferior, middle, and superior turbinates and meati), and the nasopharynx. The passage of the flexible endoscope through the nose is usually the most annoying and painful maneuver to continue the exploration of the airway to the pharynx and larynx. For this reason, it is important to develop self-assessment training systems in safe environments that allow trainees to develop the necessary skills to carry out this type of assessment with the least inconvenience and the greatest security. Despite this simulator's accurate anatomical reproduction of the tract, its suitability as a tool for endoscope exploration learning is limited without a feedback system. Effective endoscopic exploration should not cause pain or lesions, not only for comfort and safety reasons, but also because only when discomfort is minimized is a complete and detailed exploration of the anatomical structures possible. The objective of the project was to provide a feedback system from the simulator to the trainee that would facilitate improvements in self-trained skills needed to perform an endoscopic exploration of the airways. Methods: A device based on the Hall-effect sensor was designed and placed outside the airway in the upper nasal turbinate. This device detects changes in the magnetic flux, indicating a displacement on the nasal turbinate due to endoscopic maneuvers that deform the inside of the simulator and would be expected to be harmful or painful in real life. Results: The improved AirSim provides audible and visual feedback during exploration to indicate a change on the nasal turbinate due to endoscopic contact with the turbinate surface that would be expected to be harmful or painful in real life. We expect this feature to facilitate self-learning with minimal professional supervision and reduce the overall training time required to successfully perform a complete exploration of the airway. Conclusions: The inclusion of sensors on a passive simulator is a cost-effective measure that may allow for better training experiences using AirSim Multi simulator from the TruCorp company. Our improved simulator turns endoscopic exploration into a self-assessed exercise suitable for all disciplines and level of learners.
Revista:
FRONTIERS IN AGING NEUROSCIENCE
ISSN:
1663-4365
Año:
2021
Vol.:
13
Págs.:
757081
The aim of this article is to present the research protocol for a prospective cohort study that will assess the olfactory function and the effect of an intervention based on olfactory training in healthy very old adults (>= 75 years old). A convenience sample of 180 older people (50% female) will be recruited in three different environments: hospitalized control group (CH) with stable acute illness (n = 60); ambulatory control group (CA) of community-based living (n = 60); and an experimental odor training group (EOT) from nursing homes (n = 60). The odor training (OT) intervention will last 12 weeks. All the volunteers will be assessed at baseline; CA and EOT groups will also be assessed after 12 weeks. The primary end point will be change in olfactory capacity from baseline to 12 weeks period of intervention or control. The intervention effects will be assessed with the overall score achieved in Sniffin Sticks Test (SST) - Threshold, Discrimination, and Identification (TDI) extended version. Secondary end points will be changes in cognitive tasks, quality of life, mood, immune status, and functional capacity. All these measurements will be complemented with an immune fitness characterization and a deep proteome profiling of the olfactory epithelium (OE) cultured ex vivo. The current study will provide additional evidence to support the implementation of olfactory precision medicine and the development of immunomodulatory nasal therapies based on non-invasive procedures. The proposed intervention will also intend to increase the knowledge about the olfactory function in very elderly people, improve function and quality of life, and promote the recovery of the health.
Revista:
OTOLARYNGOLOGY-HEAD AND NECK SURGERY
ISSN:
0194-5998
Año:
2021
Vol.:
164
N°:
2
Págs.:
339 - 345
Objective To validate a simulator for upper airway examination, fitted with sensors, for use as an academic tool for learning how to conduct examination of the upper airway and for evaluation of that learning. Study Design Validation study. Setting Undergraduate medical education. Subjects and Methods A group of 18 fifth-year medical students and another of 6 otorhinolaryngology specialists conducted 6 examinations each with the simulator. To investigate concurrent validity, we calculated the correlation between damage scores provided by the simulator and damage assessment by a specialist. To evaluate construct validity, we compared both groups with regard to damage scores, technical procedure, and time spent. To examine content and face validity, we used questionnaires based on a 5-point Likert scale. Results For concurrent validity, the correlation between the simulator's damage scores and the specialist's damage assessment was high: Spearman's rho was 0.828 (P< .001). For construct validity, the group of students differed from the group of specialists in damage scores (P= .027) and in technical procedures (P< .001) but not in time spent. For content validity, all questionnaire statements were scored highly, and both groups had similar average scores. For face validity, the group of specialists considered the simulator to be realistic, and all statements on the questionnaire were rated with at least 4/5. Conclusion Concurrent, construct, content, and face validity have been demonstrated for a sensor-fitted simulator for upper airway examination, which is therefore accurate enough to be used as an academic tool for learning and evaluation of learning.
Revista:
JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH
ISSN:
1092-4388
Año:
2020
Vol.:
63
N°:
7
Págs.:
2177 - 2184
Objective: The aims of this study were to test the hypothesis that greater supraglottic compression (anteroposterior or lateral) correlates with higher subglottic pressure (SGP) and to develop a classification of muscle tension dysphonia (MTD), based on the degree of supraglottic compression during speech. Method: A prospective, cross-sectional study was conducted in a series of 37 consecutive patients diagnosed with MTD with an altered aerodynamic profile characterized by high SGP (more than 90 mmH(2)O). Supraglottic anteroposterior and lateral compression were categorized in three grades and assessed during the laryngoscopic examination. All patients completed the Spanish Voice Handicap Index (VHI) questionnaire and completed an acoustic and aerodynamic voice assessment. The relationship between compression grade and VHI with SGP was analyzed. Results: More than 90% of patients demonstrated some degree of anteroposterior compression, and 67% had some degree of lateral compression. The mean (SD) SGP was 111.03 (16.7) mmH(2)O, and the mean VHI was 27.86 (12.5). The degree of SGP was statistically different in the different grades of anteroposterior compression, and also anteroposterior compression correlated with an SGP (p < .05). The degree of lateral compression was not correlated with SGP. Neither the degree of anteroposterior or lateral compression nor the value of SGP was found to correlate with VHI. Conclusions: Because grade of anteroposterior compression correlates with SGP, these grades can be used for diagnosis and follow-up of MTD patients. To this end and on this basis, we propose a new classification for MTD. Unlike the established classification, our proposed one makes it possible to combine different laryngoscopic features, improving the description of the larynx during phonation.
Revista:
OTOLARYNGOLOGY CASE REPORTS
ISSN:
2468-5488
Año:
2020
Vol.:
17
Págs.:
100227
We present a case report of a 25-year-old male patient who was complaining about a sensation and noise described as a ''sponge crunching'' in the right preauricular region and right ear that was more noticeable when inflating the cheeks. Under the clinical suspicion of a pneumoparotid case, a CT scan was performed. The study revealed the presence of air in the ductal system and within the gland. The patient was diagnosed with pneumoparotid and was treated conservatively. Herein, we review the literature and discussion the management of this uncommon condition. © 2020
Autores:
Lara, J. P.; Compañ, A.; Vargas, J. A.; et al.
Revista:
EDUCACION MEDICA
ISSN:
1575-1813
Año:
2020
Vol.:
21
N°:
6
Págs.:
397 - 402
En este documento se refieren las bases legales nacionales y, más en concreto, las autonómicas andaluzas que dan respaldo a la figura del profesor contratado doctor vinculado y a la posibilidad de convocar las plazas correspondientes en las facultades de medicina de las universidades públicas españolas. Se exponen, asimismo, las características asistenciales y académicas que deben darse para llevar a cabo la convocatoria pública de dichas plazas. Se resume, a continuación, cuál es la situación actual existente en relación con dicha figura del profesorado en las facultades de medicina españolas. Se analizan también las ventajas y las posibles limitaciones que actualmente se derivan de contar con profesores contratados doctores vinculados y ello tanto para los médicos especialistas eventualmente interesados en optar a una de estas plazas como para el centro sanitario y la facultad de medicina correspondientes. Finalmente, se reseña la posible utilidad del documento elaborado por la Conferencia Nacional de Decanos de Facultades de Medicina de España (CNDFME) en la Asamblea General que se celebró en la Facultad de Medicina de Oviedo del 17 al 19 de mayo del 2018 y actualizado en marzo de 2020.
Autores:
Lara, J. P. (Autor de correspondencia); Compan, A.; Vargas-Nunez, J. A.; et al.
Revista:
REVISTA CLINICA ESPAÑOLA
ISSN:
0014-2565
Año:
2019
Vol.:
219
N°:
2
Págs.:
84 - 89
The significant and progressive reduction in the number of permanent teachers in medical schools (professor, associate professor and assistant professor) is a reason for concern for the National Conference of Deans. This reduction will intensify in the coming decade (2017-2026). Forty-three percent of the permanent faculty will retire, as will 55% of the faculty linked to clinical areas, 34% of the faculty not linked to clinical areas and 32% of the faculty of basic areas. This deficit is significant now, and, in a few years, the situation wilt be unsustainable, especially in the clinical areas. This report reveals the pressing need to adopt urgent measures to alleviate the present situation and prevent a greater problem. The training of future physicians, immediately responsible for the health of our society, depends largely on the theoretical and practical training taught in medical schools, with the essential collaboration of healthcare institutions. Paradoxically, while the number of teachers decreases substantially, there is an exponential increase in the number of medical schools and students who are admitted every year without academic or healthcare justification.
Revista:
DYSPHAGIA
ISSN:
0179-051X
Año:
2018
Vol.:
33
N°:
1
Págs.:
15 - 25
Recent studies have shown an association between alterations in laryngopharyngeal mechanosensitivity (LPMS) and dysphagia, obstructive sleep apnea, and chronic cough hypersensitivity syndrome. A previous reliability study of a new laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER) showed high intra- and inter-rater reliability; however, its accuracy has not been tested. We performed an accuracy study of the LPEER in a prospectively and consecutively recruited cohort of 118 patients at two tertiary care university hospitals. Most of the patients were suffering from dysphagia, and all of them underwent a standard clinical evaluation and fiberoptic endoscopic evaluation of swallowing with sensory testing (FEESST) using a new sensory testing protocol. The sensory test included determinations of the laryngeal adductor reflex threshold (LART), the cough reflex threshold (CRT) and the gag reflex threshold (GRT). Abnormalities on these reflex thresholds were evaluated for associations with major alterations in swallowing safety (pharyngeal residues, penetration, and aspiration). We evaluated the discriminative capacity of the LPMS test using ROC curves and the area under the curve (AUC-ROC) and its relationship with the eight-point penetration-aspiration scale (PAS) using the Spearman's ¿ correlation coefficient (SCC). We found a positive correlation between the PAS and LART (SCC 0.47; P < 0.001), CRT (SCC 0.46; P < 0.001) and GRT (SCC 0.34; P = 0.002). The AUC-ROC values for detecting a PAS ¿7 were as follows: LART, 0.83 (P < 0.0001); CRT, 0.79 (P < 0.0001); GRT, 0.72 (P < 0.0001). In this study, the LPEER showed good accuracy for evaluating LPMS. These results justify further validation studies in independent populations.
Revista:
OBESITY SURGERY
ISSN:
0960-8923
Año:
2017
Vol.:
27
N°:
7
Págs.:
1763 - 1774
BACKGROUND:
Gastric plication is a minimally invasive bariatric surgical procedure, where the greater curvature is plicated inside the gastric lumen. Our aims were to analyze the effectiveness of gastric plication on the resolution of obesity, impaired glucose tolerance, and fatty liver in an experimental model of diet-induced obesity (DIO) and to evaluate changes in glycerol metabolism, a key substrate for adiposity and gluconeogenesis, in adipose tissue and the liver.
METHODS:
Male Wistar DIO rats (n = 58) were subjected to surgical (sham operation and gastric plication) or dietary interventions [fed a normal diet (ND) or high-fat diet (HFD) or pair-fed to the amount of food eaten by gastric-plicated animals]. The expression of aquaglyceroporins (AQPs) in epididymal (EWAT) and subcutaneous (SCWAT) fat and the liver was analyzed by real-time PCR and Western blot.
RESULTS:
Gastric plication did not result in a significant weight loss in DIO rats, showing a modest reduction in whole-body adiposity and hepatic steatosis. However, gastric-plicated animals exhibited an improvement in basal glycemia and glucose clearance, without changes in hepatic gluconeogenic genes. DIO was associated with an increase in glycerol, higher AQP3 and AQP7 in EWAT and SCWAT, and a decrease in hepatic AQP9. Gastric plication downregulated AQP3 in both fat depots without changes in adipose AQP7 and hepatic AQP9.
CONCLUSION:
Gastric plication results in a modest reduction in adiposity and hepatosteatosis but restores glycemia by downregulating AQP3, which entails lower efflux of glycerol from fat, lower plasma glycerol availability, and a reduced use of glycerol as a substrate for hepatic gluconeogenesis.
Autores:
Giraldo-Cadavid, L. F. (Autor de correspondencia); Burguete, Javier; Rueda, F.; et al.
Revista:
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY
ISSN:
0937-4477
Año:
2017
Vol.:
274
N°:
7
Págs.:
2861 - 2870
BACKGROUND:
There are not reliable methods for measuring laryngo-pharyngeal mechano-sensitivity (LPMS). We aimed to determine the reliability of a new method for measuring LPMS using a new laryngo-pharyngeal esthesiometer (LPEER) in a prospective cohort of dysphagic stroke and non-dysphagic patients. The patients underwent clinical and endoscopic evaluations of swallowing (FESSST). The LPMS assessments consisted of measurements by an expert and a novel rater of the laryngeal-adductor reflex threshold (LART), cough reflex threshold (CRT) and gag reflex threshold (GRT) using the LPEER. We assessed the Bland-Altman limits of agreement, the intraclass correlation coefficients (ICCs) and Spearman correlation coefficients (SCCs). For the inter-rater comparisons, we contrasted the expert and novel raters. A total of 1608 measurements were obtained from 34 dysphagic stroke patients and 33 non-dysphagic patients. The intra-rater ICCs for all reflex thresholds were >0.90. The inter-rater ICCs were 0.87 for the LART, 0.79 for the CRT and 0.70 for the GRT. The intra-rater SCCs for all reflex thresholds were above 0.88 (P¿<¿0.0001). The inter-rater SCC were 0.80 for the LART, 0.79 for the CRT and 0.70 for the GRT (all P¿<¿0.0001). The Bland-Altman plots revealed good agreement for the LART and CRT and moderate agreement for the GRT. The median normal value was 0.14 mN for the LART, 4.4 mN for the CRT and 11.9 mN for the GRT. The median thresholds values in patients with aspiration were LART: 1.31 mN; CRT: 32.9 mN and GRT: 32.9 mN (all P¿<¿0.006 vs normal thresholds). The LPEER exhibited substantial to excellent intra- and inter-rater reliability.
Autores:
Giraldo-Cadavid, L. F. ; Agudelo-Otalora, L. M.; Burguete, Javier; et al.
Revista:
BIOMEDICAL ENGINEERING ONLINE
ISSN:
1475-925X
Año:
2016
Vol.:
15
N°:
1
Págs.:
52
BACKGROUND:
Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity.
METHODS:
We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes.
RESULTS:
We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducti
Revista:
JOURNAL OF VOICE
ISSN:
0892-1997
Año:
2016
Vol.:
30
N°:
1
Págs.:
114 -119
Objective The purpose of this study was to detect specific vocal aerodynamic patterns in attention deficit hyperactivity disorder (ADHD) patients and to define a possible new phenotypic feature of this disorder that must be diagnosed and treated.
Study Design This is a prospective study.
Methods Seventy-nine children aged 5¿13 years were recruited: 44 children with ADHD diagnosis and 35 children, as a control group, matched according to age and gender. All children were evaluated in the voice laboratory. Each subject repeated sustained vowels, syllables, words, and sentences several times. Intraoral pressure, transglottal airflow, microphone, and electroglottograph results were recorded and analyzed. Children affected by ADHD, with adequate tolerance, were evaluated endoscopically and by the speech therapist.
Results The aerodynamic analysis shows that the subglottal pressure is higher and transglottal airflow is lower in ADHD children compared with the children of the control group. Those differences are statistically significant. The endoscopic physical examination showed vocal nodules in 25 children (78.125%) and hyperfunctional vocal behavior in all ADHD children studied.
Conclusions We proposed that every child with ADHD disorder must be evaluated from a laryngeal point of view (otolaryngologist and speech therapist) as an important part of the diagnosis and global treatment. It could be considered as a new phenotypic characteristic of this disorder.
Autores:
Busto-Crespo, O; Uzcanga Lacabe, M; Abad Marco, A; et al.
Revista:
JOURNAL OF VOICE
ISSN:
0892-1997
Año:
2016
Vol.:
30
N°:
6
Págs.:
767.e9-767e15.
Voice therapy is effective in patients with UVFP and its benefits are sustained over time. Early referral for voice therapy seems to be associated with greater benefit, but quality of life also improves for patients despite delayed treatment.
Revista:
OBESITY SURGERY
ISSN:
0960-8923
Año:
2016
Vol.:
26
N°:
7
Págs.:
1549-58
Background
Aging and obesity are two conditions associated with increased risk of cardiovascular disease. Our aim was to analyze whether an advanced age affects the beneficial effects of sleeve gastrectomy on weight loss and blood pressure in an experimental model of diet-induced obesity (DIO).
Methods
Young (6-month-old) and old (18-month-old) male Wistar DIO rats (n¿=¿101) were subjected to surgical (sham operation and sleeve gastrectomy) or dietary interventions (pair-fed to the amount of food eaten by sleeve gastrectomized animals). Systolic (SBP), diastolic (DBP), and mean (MBP) blood pressure values and heart rate (HR) were recorded in conscious, resting animals by non-invasive tail-cuff plethysmography before and 4 weeks after surgical or dietary interventions.
Results
Aging was associated with higher (P¿<¿0.05) body weight and subcutaneous and perirenal fat mass as well as mild cardiac hypertrophy. Sleeve gastrectomy induced a reduction in body weight, whole-body adiposity, and serum total ghrelin in both young and old DIO rats. The younger group achieved a higher excess weight loss than the older group (164¿±¿60 vs. 82¿±¿17 %, P¿<¿0.05). A significant (P¿<¿0.05) decrease in insulin resistance, SBP, DBP, MBP, and HR without changes in heart weight was observed after sleeve gastrectomy independently of age.
Conclusion
Our results provide evidence for the effectiveness of sleeve gastrectomy without increased operative risk in body weight and blood pressure reduction
Revista:
OBESITY SURGERY
ISSN:
0960-8923
Año:
2016
Vol.:
26
N°:
7
Págs.:
1537-48
Background: Susceptibility to obesity is associated with a notable inter-individual variation. The aim of the present study was to compare the effectiveness of sleeve gastrectomy (SG) on weight loss and metabolic profile in obesity-prone (OP) rats vs animals that are non-susceptible to obesity (NSO). Methods: Young male Wistar rats (n = 101) were put in a diet-induced obesity (DIO) programme with ad libitum access to a high-fed diet (HFD) during 12 months. Body weight and food intake were regularly registered. Thereafter, rats were ranked by final body weight to identify the obesity-prone (OP) (n = 13) and non-susceptible to obesity (NSO) (n = 14) animals. OP and NSO rats were submitted to surgical interventions (sham operation, SG and pair-fed to the amount of food eaten by sleeve-gastrectomized rats). Body weight, food intake, energy expenditure, body temperature, fat pads weight, and metabolic profiling were analysed 4 weeks after surgical or dietary interventions. Results: SG in both OP and NSO rats decreased body weight as compared to sham and pair-fed groups (P < 0.05), mainly due to reductions in subcutaneous and perirenal fat mass (P < 0.001). Total weight loss achieved in sleeve-gastrectomized OP and NSO rats was higher than that of pair-fed ones (P < 0.05), showing that the SG effect goes beyond caloric restriction. In this regard, sleeve-gastrectomized rats exhibited significantly (P < 0.05) increased basal rectal temperature together with upregulated brown adipose tissue Ucp-1 protein expression levels. A significant (P < 0.05) improvement in insulin sensitivity was also observed in both OP and NSO animals that underwent SG as compared with pair-fed counterparts. Conclusion: Our findings provide the first evidence that obesity-prone rats also benefit from surgery responding effectively to SG, as evidenced by the significant body weight reduction and the metabolic profile improvement.
Autores:
Busto Crespo, O.; Uzcanga Lacabe, M.; Abad Marco, A.; et al.
Revista:
ANALES DEL SISTEMA SANITARIO DE NAVARRA
ISSN:
1137-6627
Año:
2016
Vol.:
39
N°:
1
Págs.:
69 - 75
BACKGROUND:
To describe demographic factors and voice quality parameters of patients with unilateral vocal fold paralysis (UVFP) after a voice therapy protocol.
METHODS:
Forty-seven patients with a diagnosis of UVFP by video-laryngoscopy were included. Voice therapy was applied to all patients during 15 sessions that were structured in three progressive stages. The objective was to train patients in vocal techniques, phonic-breathing coordination,blow control, vocal exercises for glottic closure and vocal setting. Glottal closure, Voice Handicap Index-10 for perception of voice impairment and GRBAS scale were used before and after the speech therapy.
RESULTS:
The average age was 51 years (range 20-80), 60%women. Surgery was the most frequent cause (72%), and 40% had a profession related to voice use. Median time from diagnosis to treatment was 5 months (2-12). After voice therapy, 80% had complete glottal closure, previously this had been 34% (p<0.001), the score of VHI-10 decreased from 24.24 to 16.09 points (p<0.001) and GRBAS values improved in all the qualities of voice (p<0.001).Only 8.5% of the patients required surgical intervention after treatment.
CONCLUSIONS:
Voice therapy is effective as first line therapy in patients with UVFP, reserving medialization with non-absorbable material or thyroplasty surgery for those with a poor outcome. However, it is necessary to reduce the time it takes the patient to reach the Voice Unit after laryngoscopic diagnosis.
Revista:
CLINICAL AUTONOMIC RESEARCH
ISSN:
0959-9851
Año:
2015
Vol.:
25
N°:
4
Págs.:
225 - 232
BACKGROUND:
Cardiac autonomic tone after long-term continuous positive airway pressure therapy in patients with obstructive sleep apnea remains unexplored.
METHODS:
Thirty patients with obstructive sleep apnea (14 with moderate and 16 with severe obstructive sleep apnea) were studied during a baseline polysomnographic study, after a full night of acute continuous positive airway pressure treatment, and after long-term (~2 years) chronic continuous positive airway pressure therapy. Twenty age- and gender-matched controls with baseline sleep study were selected for comparison purposes. Cross-spectral analysis and the low-frequency (LF) and high-frequency (HF) components of the heart rate variability were computed separately over 10-min ECG epochs during rapid eye movement sleep, non-rapid eye movement sleep, and wakefulness.
RESULTS:
During the baseline study, obstructive sleep apnea patients exhibited increased LF, decreased HF, and increased LF/HF ratio during sleep when compared to controls. In a multiple regression model, the mean oxygen saturation explained the increased LF during rapid and non-rapid eye movement sleep in obstructive sleep apnea patients. Acute continuous positive airway pressure therapy decreased the LF modulations and the LF/HF ratio and increased the HF modulations during sleep in patients with severe obstructive sleep apnea. Long-term continuous positive airway pressure therapy decreased LF modulations and LF/HF ratio with increased HF modulations during sleep in patients with moderate and severe obstructive sleep apnea.
CONCLUSIONS:
Long-term continuous positive airway pressure reduces the sympathovagal imbalance in patients with moderate and severe obstructive sleep apnea, both during rapid and non-rapid eye movement sleep. Continuous positive airway pressure seems to exert its changes in cardiac autonomic modulation by decreasing the burden of nocturnal hypoxia.
Revista:
OBESITY SURGERY
ISSN:
0960-8923
Año:
2015
Vol.:
25
N°:
9
Págs.:
1723 - 1734
BACKGROUND:
Glycerol constitutes an important metabolite for the control of lipid accumulation and glucose homeostasis. Our aim was to investigate the potential role of aquaglyceroporins, which are glycerol channels mediating glycerol efflux in adipocytes (AQP3 and AQP7) and glycerol influx (AQP9) in hepatocytes, in the improvement of adiposity and hepatic steatosis after sleeve gastrectomy in an experimental model of diet-induced obesity (DIO).
METHODS:
Male Wistar DIO rats (n = 161) were subjected to surgical (sham operation and sleeve gastrectomy) or dietary interventions [fed ad libitum a normal diet (ND) or a high-fat diet (HFD) or pair-fed to the amount of food eaten by sleeve-gastrectomized animals]. The tissue distribution and expression of AQPs in biopsies of epididymal (EWAT) and subcutaneous (SCWAT) white adipose tissue and liver were analyzed by real-time PCR, Western blot, and immunohistochemistry.
RESULTS:
Four weeks after surgery, DIO rats undergoing sleeve gastrectomy showed a reduction in body weight, whole-body adiposity, and hepatic steatosis. DIO was associated with a tendency towards an increase in EWAT AQP3 and SCWAT AQP7 and a decrease in hepatic AQP9. Sleeve gastrectomy downregulated AQP7 in both fat depots and upregulated AQP3 in EWAT, without changing hepatic AQP9. Aqp7 transcript levels in EWAT and SCWAT were positively associated with adiposity and glycemia, while Aqp9 mRNA was negatively correlated with markers of hepatic steatosis and insulin resistance.
CONCLUSION:
Our results show, for the first time, that sleeve gastrectomy, a widely applied bariatric surgery procedure, restores the coordinated regulation of fat-specific AQP7 and liver-specific AQP9, thereby improving whole-body adiposity and hepatic steatosis.
Revista:
CLINICAL NEUROPHYSIOLOGY
ISSN:
1388-2457
Año:
2014
Vol.:
125
N°:
9
Págs.:
1783 - 1791
OBJECTIVE:
The pathophysiological basis of obstructive sleep apnea (OSA) is not completely understood and likely varies among patients. In this regard, some patients with OSA do not exhibit hypoxemia. We aimed to analyze the clinical, sleep, and autonomic features of a group of patients with severe OSA without hypoxia (OSA-h) and compare to OSA patients with hypoxia (OSA+h) and controls.
METHODS:
Fifty-six patients with OSA-h, 64 patients with OSA+h, and 44 control subjects were studied. Clinical and sleep features were analyzed. Besides, time- and frequency-domain heart rate variability (HRV) measures comprising the mean R-R interval, the standard deviation of the RR intervals (SDNN), the low frequency (LF) oscillations, the high frequency (HF) oscillations, and the LF/HF ratio, were calculated across sleep stages during a one-night polysomnography.
RESULTS:
OSA-h patients had a lower body mass index, a lower waist circumference, lower apnea duration, and a higher frequency of previous naso-pharyngeal surgery when compared to OSA+h patients. In terms of heart rate variability, OSA+h had increased LF oscillations (i.e., baroreflex function) during N1-N2 and rapid eye movement (REM) sleep when compared to OSA-h and controls. Both OSA+h and OSA-h groups had decreased HF oscillations (i.e., vagal inputs) during N1-N2, N3 and REM sleep when compared to controls. The LF/HF ratio was increased during N1-N2 and REM sleep, only in patients with OSA+h.
CONCLUSIONS:
Patients with OSA-h exhibit distinctive clinical, sleep, and autonomic features when compared to OSA with hypoxia.
SIGNIFICANCE:
OSA is a heterogeneous entity. These differences must be taken into account in future studies when analyzing therapeutic approaches for sleep apnea patients.
Revista:
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES
ISSN:
0930-2794
Año:
2014
Vol.:
28
N°:
2
Págs.:
2412 - 2420
Background
Bariatric surgery (BS) has proven to be an effective treatment for morbid obesity. Osteopontin (OPN) is a proinflammatory cytokine involved in the development of obesity. The aim of our study was to determine the effect of weight loss following BS on circulating levels of OPN in humans.
Methods
Body composition and circulating concentrations of OPN and markers of bone metabolism were determined in obese patients who underwent Roux-en-Y gastric bypass (RYGB; n = 40) or sleeve gastrectomy (SG; n = 11).
Results
Patients who underwent RYGB or SG showed decreased body weight (P < 0.001) and body fat percentage (P < 0.001) as well as lower insulin resistance. However, plasma OPN levels were significantly increased after RYGB (P < 0.001) but remained unchanged following SG (P = 0.152). Patients who underwent RYGB also showed significantly increased C-terminal telopeptide of type-I collagen (ICTP) (P < 0.01) and osteocalcin (P < 0.001) while bone mineral density tended to decrease (P = 0.086). Moreover, OPN concentrations were positively correlated with the bone resorption marker ICTP after surgery. On the other hand, patients who underwent SG showed significantly increased ICTP levels (P < 0.05), and the change in OPN was positively correlated with the change in ICTP and negatively with the change in vitamin D after surgery (P < 0.05).
Conclusions
RYGB increased circulating OPN levels, while they remained unaltered after SG. The increase in OPN levels after RYGB could be related to the increased bone resorption in relation to its well-known effects on bone of this malabsorptive procedure in comparison to the merely restrictive SG.
Revista:
SIMULATION IN HEALTHCARE
ISSN:
1559-2332
Año:
2013
Vol.:
8
N°:
4
Págs.:
234 - 241
Introduction: Current European Resuscitation Guidelines 2010 recommend the use of prompt/feedback devices when training for cardiopulmonary resuscitation (CPR). We aimed to assess the quality of CPR training among second-year medical students with a voice advisory mannequin (VAM) compared to guidance provided by an instructor.
Methods: Forty-three students received a theoretical reminder about CPR followed by a 2-minute pretest on CPR (compressions/ventilations cycle) with Resusci Anne SkillReporter (Laerdal Medical). They were then randomized into a control group (n = 22), trained by an instructor for 4 minutes per student, and an intervention group (n = 21) trained individually with VAM CPR mannequin for 4 minutes. After training, the students performed a 2-minute posttest, with the same method as the pretest.
Results: Participants in the intervention group (VAM) performed more correct hand position (73% vs. 37%; P = 0.014) and tended to display better compression rate (124 min-1 vs. 135 min-1; P = 0.089). In a stratified analyses by sex we found that only among women trained with VAM was there a significant improvement in compression depth before and after training (36 mm vs. 46 mm, P = 0.018) and in the percentage of insufficient compressions before and after training (56% vs. 15%; P = 0.021).
Conclusions: In comparison to the traditional training method involving an instructor, training medical students in CPR with VAM improves the quality of chest compressions in hand position and in compression rate applied to mannequins. Only among women was VAM shown to be superior in compression depth training. This technology reduces costs in 14% in our setup and might potentially release instructors' time for other activities.
Revista:
SLEEP
ISSN:
0161-8105
Año:
2013
Vol.:
36
N°:
6
Págs.:
933 - 940
OBJECTIVE:
To assess autonomic function by heart rate variability (HRV) during sleep in patients with sleep related alveolar hypoventilation (SRAH) and to compare it with that of patients with obstructive sleep apnea (OSA) and control patients.
DESIGN:
Cross-sectional study.
SETTING:
Sleep Unit, University Hospital of University of Navarra.
PATIENTS:
Fifteen idiopathic and obesity related-SRAH patients were studied. For each patient with SRAH, a patient with OSA, matched in age, sex, body mass index (BMI), minimal oxygen saturation (SatO2), and mean SatO2 was selected. Control patients were also matched in age, sex, and BMI with patients with OSA and those with SRAH, and in apnea/hypopnea index (AHI) with patients with SRAH.
INTERVENTIONS:
N/A.
MEASUREMENTS AND RESULTS:
Time- and frequency-domain HRV measures (R-R, standard deviation of normal-to-normal RR interval [SDNN], very low frequency [VLF], low frequency [LF], high frequency [HF], LF/HF ratio) were calculated across all sleep stages as well as during wakefulness just before and after sleep during a 1-night polysomnography. In patients with SRAH and OSA, LF was increased during rapid eye movement (REM) when compared with control patients, whereas HF was decreased during REM and N1-N2 sleep stages. The LF/HF ratio was equally increased in patients with SRAH and OSA during REM and N1-N2. Correlation analysis showed that LF and HF values during REM sleep were correlated with minimal SatO2 and mean SatO2.
CONCLUSIONS:
Patients with SRAH exhibited an abnormal cardiac tone during sleep. This fact appears to be related to the severity of nocturnal oxygen desaturation. Moreover, there were no differences between OSA and SRAH, supporting the hypothesis that autonomic changes in OSA are primarily related to a reduced nocturnal oxygen saturation, rather than a consequence of other factors such as nocturnal respiratory events.
Revista:
SLEEP MEDICINE
ISSN:
1389-9457
Año:
2013
Vol.:
14
N°:
2
Págs.:
217 - 219
Objectives
This is a video case report of a 58-year-old male patient with severe obstructive sleep apnea (OSA) who underwent a pharyngo-laryngoscopy during non-drug-induced sleep.
Methods
The pharyngo-laryngoscopy was performed transnasally during a 30-minute nap, in the afternoon, with a flexible endoscope in supine position. During the procedure, the patient was monitored with polysomnography.
Results
The patient slept for 20 minutes in supine position, reaching N2 sleep stage. During the sleep, 15 respiratory events (apneas or hypopneas) were recorded. The video-recording showed that, during apneas, the obstruction at the pharyngeal level was never complete, although the nasal sensor showed a total stop in the nasal airflow.
Conclusions
This case highlights that OSA could not be as obstructive as generally thought, at least during N2 sleep; moreover, it suggests that apneic episodes are not a totally passive and monomorphic phenomenon, but a rather complex event.
Revista:
OBESITY SURGERY
ISSN:
0960-8923
Año:
2012
Vol.:
22
N°:
4
Págs.:
634 - 640
Background: Sleeve gastrectomy (SG) has been used as a multipurpose surgical procedure for the treatment of morbid obesity. The aim of the study was to analyze gastric morphology and histology at two different time points after SG in rats. Methods: Thirty-five male Wistar rats were fed ad libitum during 3 months on a high-fat diet to induce obesity. Subsequently, 25 diet-induced obese rats underwent either SG (n=12) or a sham operation (n=13). The remaining ten obese animals encompassed the nonoperated control group (Co). Four weeks postoperatively, 15 rats (n05 rats/experimental group) were sacrificed, while the remaining 20 rats were sacrificed after 16 weeks (animals/group; Co=5, sham=8, SG=7) to compare the gastric morphological and histopathological changes over time. Body weight and food intake were regularly recorded. Results: For both time periods, the Co groups exhibited the highest body weight, while the rats undergoing the SG showed the lowest weight gain (P<0.05). Initially, significant differences (P<0.005) in food intake relative to body weight were observed between the Co rats and animals undergoing surgery, which disappeared thereafter. The actual total stomach sizeafter both experimental periods in the SG group was similar to that of non- and sham-operated rats mainly due to a forestomach enlargement, which was more pronounced after 16 weeks. Traits of gastritis cystica profunda characterized by gastric foveolae elongation with hyperplasia and cystic dilatation of the glandswere observed in the residual stomachs of the sleeve-gastrectomized rats. These findings were mostly observed after 16 weeks of performing the SG, although they were also detected occasionally following 4 weeks postoperatively. No intestinal metaplasia was observed. Conclusion: After SG gastric macro- and microscopic changes with functional implications in both the short and long term take place.
Revista:
BRITISH JOURNAL OF DERMATOLOGY
ISSN:
0007-0963
Año:
2012
Vol.:
167
N°:
5
Págs.:
1011 - 1016
Summary Background¿ Pemphigus vulgaris (PV) is an autoimmune blistering skin disorder characterized by the presence of suprabasal acantholysis and autoantibodies against desmoglein 3. There are two different clinical forms: mucocutaneous (MCPV) and mucosal (MPV). However, little is known about PV lesions in oral, ear, nose and throat (OENT) areas produced by the very dynamic of the anatomical structures involved in the functions of the aerodigestive tract.
Objectives¿ To investigate the pattern of OENT manifestations in PV, and their relationship with physiological traumatic mechanisms in stratified squamous epithelial structures.
Methods¿ A prospective analysis of 40 patients diagnosed with MCPV (22 patients) or MPV (18 patients) was carried out at the University Clinic of Navarra. OENT manifestations were evaluated in all patients endoscopically. OENT involvement was divided into anatomical areas.
Results¿ The most frequent symptom was pain, mainly on oral mucosa (87·5%). Buccal mucosa (90%), posterior wall of pharynx (67·5%), upper edge of epiglottis (85%) and nasal vestibule (70%) were the areas most frequently affected in the OENT mucosa. These localizations were related to physiological traumatic mechanisms in polystratified squamous epithelial structures.
Conclusions¿ OENT endoscopy should be included in the examination of all patients with PV. Knowledge of the most frequent localizations of active lesions on OENT mucosa in PV will help us to interpret more efficiently the findings from OENT endoscopy. Also, information related to traumatic physiological mechanisms on OENT areas must be offered to patients in order to avoid the appearance of new active PV lesions.
Revista:
OBESITY SURGERY
ISSN:
0960-8923
Año:
2011
Vol.:
21
N°:
9
Págs.:
1438 - 1443
Background: Sleeve gastrectomy (SG) has been used for the surgical treatment of morbid obesity as a first or definitive procedure with satisfactory results. The objective of this study in rats was to establish the effects of SG on weight loss depending on the post-surgical type of diet followed. Methods: Thirty male Wistar rats were fed ad libitum during 3 months on a high-fat diet (HFD) to induce obesity. After this first phase, rats were subdivided in three groups of ten rats each and underwent a sham intervention, an SG, or no surgery but were pair-fed to the amount of food eaten by the animals of the SG group. At this time point, half of the animals in each group continued to be fed on the HFD, while the other half was switched to a normal chow diet (ND). Thus, the following subgroups were established: sham-ND, sleeve-ND, pair-fed-ND as well as sham-HFD, sleeve-HFD, and pair-fed-HFD. Body weight and food intake were recorded daily for 4 weeks. The feed efficiency rate (FER) was determined from weekly weight gains and caloric consumption during this period. Results: Statistically significant (P¿<¿0.05) differences in body weight were observed between the six experimental groups after 4 weeks of the interventions with rats in the sleeve-ND group experimenting the highest weight loss (-78.2¿±¿10.3 g) and animals in the pair-fed-HFD group exhibiting the lowest weight reduction (-4.0¿±¿0.1 g). Interestingly, the FER value of rats that underwent the SG and continued to be fed on a HFD was significantly (P¿<¿0.05) lower than that of sham operated and pair-fed animals on the same diet. Conclusion: The positive effects of SG on weight reduction are observed in obese rats submitted to the intervention and subsequently following an ND or even an HFD.
Revista:
SLEEP AND BREATHING
ISSN:
1520-9512
Año:
2011
Vol.:
15
N°:
2
Págs.:
229 - 235
Purpose: Catathrenia (nocturnal groaning) is a rare and relatively little-understood parasomnia. The characteristics of the sound and the recordings are not similar in all the relevant research papers. Indeed, there is currently some discussion regarding whether or not this is a single entity. For some authors, catathrenia is a particular form of parasomnia; for others, it may be a variant of snoring or a respiratory problem. The goal is to establish whether or not catathrenia may be regarded as an expiratory vocal sound. An attempt was made to classify the origin of this sound according to its sound structure. Methods: We present the sound analysis of two patients, a man and a woman, with clinically diagnosed catathrenia and we compared them with the analysis of snoring. We use the spectrogram and the oscillogram. We classified the sounds according to the Yanagihara criteria. Results: The vocal nature of the sound was confirmed, and several significant differences to some snoring sounds were discovered. The analysis of the catathrenia samples demonstrated that these signals are type II according to Yanagihara classification; these signals had a very short jitter, and had formants and harmonics. However, snoring is a type III, very irregular and had formants but not harmonics. Conclusions: The oscillogram and the spectrogram in these patients show that the origins of the sounds are clearly different: catathrenia is laryngeal, while snoring is guttural. Catathrenia cannot be considered as expiratory snoring.
Revista:
AURIS NASUS LARYNX
ISSN:
0385-8146
Año:
2010
Vol.:
37
N°:
4
Págs.:
409 - 414
Objective: To evaluate the value of different variables of the clinical history, auditory and vestibular tests and handicap measurements to define intractable or disabling Meniere's disease. Methods: This is a prospective study with 212 patients of which 155 were treated with intratympanic gentamicin and considered to be suffering a medically intractable Meniere's disease. Age and sex adjustments were performed with the 11 variables selected. Discriminant analysis was performed either using the aforementioned variables or following the stepwise method. Results: Different variables needed to be sex and/or age adjusted and both data were included in the discriminant function. Two different mathematical formulas were obtained and four models were analyzed. With the model selected, diagnostic accuracy is 77.7%, sensitivity is 94.9% and specificity is 52.8%. Conclusion: After discriminant analysis we found that the most informative variables were the number of vertigo spells, the speech discrimination score, the time constant of the VOR and a measure of handicap, the "dizziness index". (C) 2009 Elsevier Ireland Ltd. All rights reserved.